QY Electrical Insulation Overhead Crane

An insulated overhead crane uses electrical isolation at selected load-path connections to reduce the risk of current reaching the crane through a lifted component. It is intended for non-ferrous metal processing and electrolysis areas, with insulation performance, contamination and the electrical operating conditions assessed as part of the project.

QY electrical insulation overhead crane for electrolysis and strong current process areas
QY insulated overhead crane with bridge structure and electrically isolated lifting arrangement for strong-current, high-temperature and corrosive industrial environments.

At a glance

QY example capacity
5 t
QY example span
10.5, 13.5, 16.5, 19.5, 22.5, 25.5, 28.5 or 31.5 m
QY example lift
16 m
QY example duty
A5

DGCRANE QY 5 t/A5 catalogue example. The insulation arrangement and electrical test requirements must be matched to your electrolytic process.

Where it is used

Electrolysis workshops

Handle components around equipment where the load may create an electrical conduction path.

Non-ferrous metal production

Lift process parts in aluminum, magnesium or other suitable smelting operations.

Process maintenance

Remove equipment using an isolation arrangement matched to the plant electrical conditions.

Product features

Isolated load path

Insulating pads, sleeves and plates interrupt selected electrical conduction paths.

Controlled positioning

Drive and speed-control arrangements support careful placement near process equipment.

Inspection access

The isolation arrangement is selected together with its inspection and maintenance requirements.

Technical specifications

Model: QY

ModelQY
Control methodCabin/ground handle/wireless remote
Working dutyA4 – A6
Hoisting speed0.8m/min – 10m/min
Crane travel speed10m/min – 30m/min
Trolley travel speed8m/min – 25m/min
Power supply380V/50Hz; 220V-660V/60Hz
Protection levelIP65
Electrical isolationInsulating pads, sleeves and plates at selected lifting connections
Process applicationHandling near high-current non-ferrous metal equipment
Load positioningControlled hoisting and travel speeds
DGCRANE QY reference rated capacity5 t
DGCRANE QY reference span options10.5, 13.5, 16.5, 19.5, 22.5, 25.5, 28.5 or 31.5 m
DGCRANE QY reference lifting height16 m
DGCRANE QY reference working dutyA5
DGCRANE QY reference hoisting speed12.5 m/min
DGCRANE QY reference trolley speed37.2 m/min

Published selection ranges are configuration dependent. Rated load, span, height, speed and duty are confirmed together in the project drawing.

Price guide

Request a configuration-specific price for this crane. The quotation is based on the lifting task, site dimensions and the equipment scope below.

What affects the price?

  • Load rating, process voltage and isolation arrangement
  • Thermal exposure, contamination and inspection requirements
  • Motion controls, electrical supply and destination requirements
  • Freight, runway structure, installation and commissioning scope
Get a quotation for this product

Typical configurations

Electrical isolation

Insulating pads, sleeves and plates at designated interfaces

Agree the required insulation boundaries and acceptance checks.

Motion control

Precision drive and speed-control arrangement

Match load transfer and final placement to the process.

Lifting arrangement

Hook lifting for electrically sensitive process work

Specify load, attachment and process conditions alongside the insulation requirements.

Final capacity, dimensions and operating functions are agreed for your load and site.

Compare related models

Compare the lifting arrangement and site layout before choosing a model.

Configuration

Combines electrical insulation with two trolley lifting systems capable of independent or coordinated operation.

Consider it when

Electrical isolation is required and long, large or complex loads require two separated lifting positions or tandem handling.

Configuration

Uses explosion-protected mechanical and electrical equipment for classified gas, vapor or combustible-dust environments rather than electrical isolation from energized process equipment.

Consider it when

The primary hazard is ignition of a classified explosive atmosphere rather than conductive current transfer through the crane structure.

Configuration

Dedicated metallurgical crane configured around molten-metal handling, severe heat exposure and ladle lifting rather than electrical isolation as the primary design requirement.

Consider it when

The crane directly handles molten metal or ladles and requires a dedicated metallurgical lifting and safety architecture.

Plan your crane specification

Provide process voltage information, energized zones, intended isolation points and drawings of the lifting device and load connection. State the required insulation performance, test method, acceptance criteria and any inspection or cleaning procedure.

Add maximum and typical lifting loads, load dimensions, operating cycle, shifts and positioning requirements. Include the runway span and length, hook elevations, building support limits and nearby process equipment.

Describe ambient and process temperatures, corrosive exposure, moisture and contamination. These inputs help establish the lifting arrangement, insulating interfaces, environmental protection and maintenance provisions as a coordinated process-specific crane specification.

Frequently asked questions

Is the QY an explosion-proof crane?

Electrical insulation and explosion protection address different requirements. If the process also involves a classified hazardous area, provide that classification separately so both needs can be assessed.

Can an insulation voltage be selected without process drawings?

The required isolation interfaces, operating conditions and acceptance tests must be defined for the installation. Process and lifting-device drawings are needed to establish a meaningful specification.

Why are cleaning and inspection requirements relevant?

Process deposits, moisture and environmental exposure can affect insulating interfaces. Include the operating environment and required maintenance method when defining the insulation and testing scope.

Product views and components

YOUR LIFTING PROJECT

Let's find the right crane for your application.

Share the lifting task and the details you already know. A drawing or a clear description helps us review your requirements.

  • Load, dimensions & lifting attachment
  • Span, lifting height & working area
  • Operating frequency & environment
  • Destination, power supply & project scope

Still defining the specification? Mark unknown items as “to be confirmed”.

    Henan Mine Crane uses the contact details and project information you submit to review your enquiry, prepare a response and discuss the requested crane supply or service. Please include only information needed for your project. Questions about your enquiry information? Contact info@hnksglobal.com. Privacy Notice.